Emptying systems

Pressing out liquid and pasty media from cartridges.

All liquid media are delivered in so-called containers. There are many different sizes.

The small containers most commonly used in the industry are Euro 310 ml or Semco 90, 180, 360, 600, 900 ml cartridges.

Axiss has specialized in emptying these small containers.

Large containers are 5, 10, 20 200l drums.

Before a product can be dosed, it must be able to be removed from the container.

With us you will find the matching container emptying for the original container.

The "cartridge empty" status can be queried via a fill level sensor. However, this must be connected externally with 24V.


Integrated in a dosing system, the dosing head is used next to emptying directly afterwards.

See 1K valves. This gives you a complete system from a single source.

Container emptying of Semco cartridges

 

Pneumatic container emptying for semi-cartridges of 180-900 ccm content. With a folding mechanism for changing the cartridges.

The cylinder is slowly moved into the cartridge with the hand lever valve.

The setting on the manometer changes the pressure on the cartridge and thus the flow rate.

Connection options for dosing valves such as dispensers via a material hose.

 

Technical description

  • Pneumatic cylinder with throttle valves

  • Pneumatic hand lever valve

  • Pressure regulator with manometer 0 - 6 bar

  • Folding unit for changing the cartridges

 

 

9110 Emptying system

          Semco 600 ml

Size approx.:

765 x 255 x 133 mm (L / W / D)

Behälterentleernung für Dosieranlage axiss Dosiertechnik

9112 Emptying system

           Semco 900 ml

Size approx.:

967 x 255 x 130 mm (L / W / D)

9112 Behälterentleernung für Dosieranlage

9113 Emptying system

           Semco 180 ml

Size approx.:

647 x 255 x 140 mm (L / W / D)

9113  Behälterentleernung Semco 180ml  für Dosierung axiss Dosiertechnik

9114 Emptying system

           Semco 360 ml

Size approx.:

970 x 180 x 135 mm (L / W / D)

9114 Behälterentleernung Semco 180ml  für Dosierung axiss Dosiertechnik

Double container emptying for Semco cartridges

 

Double extrusion units for liquid and pasty media from Semco cartridges

 

Pneumatic, double container emptying for semi-cartridges from 180 - 900 ml.
With a folding mechanism for changing the cartridges.

The container cartridges are released and pressed out alternately via the material switch, reset buttons and control.
This enables a seamless supply of material to metering valves, eg dispensers, etc.

The currently active container is indicated by a lamp. Connection options for metering valves via the material hose.

The container emptying works independently via an internal control and also send signals to the outside.

The setting on the pressure gauges changes the pressure on the cartridges and thus the flow rate.

 

Technical description

  • Pneumatic cylinder with throttle valves

  • Pneumatic hand lever valves

  • Material switch for alternate pressing

  • Pressure regulator with manometers 0 - 6 bar

  • Folding units for changing the cartridges

 

9117 Emptying system

           Semco 2x 900 ml

Size approx.:

1308 x 499 x 191 mm (L / W / D)

9117 Behälterentleernung Semco 2x900ml  für Dosierung axiss Dosiertechnik

9119 Emptying system

           Semco 2x 600 ml

Size approx.:

1108 x 440 x 191 mm (L / W / D)

2K Electroventil E400
2K Electroventil E400

press to zoom
2K DUO cartridges
2K DUO cartridges

press to zoom
Changeable cartridge holder
Changeable cartridge holder

press to zoom
2K Electroventil E400
2K Electroventil E400

press to zoom
1/3

9121 Emptying system

           Semco 2x 180 ml

Size approx.:

647 x 255 x 140 mm (L / W / D)

9121 Behälterentleernung Semco 2x180ml  für Dosierung axiss Dosiertechnik

Euro cartridges

 

Pressing out liquid and pasty media from Euro cartridges

Cartridge pressure container for dispensing from 310 ml Euro cartridges.

The maximum pressurization in these containers is 0-6 bar.
The pressure is applied directly via cartridge stoppers or by means of an integrated pneumatic piston.

The setting on the manometer changes the pressure on the cartridge and thus the flow rate.

 

Options

  • Magnetic limit sensor Art.No. 9020-9999

  • Level sensor Art.No. 7002-0004 (with pneumatic piston)

  • 2-way ball valve for venting the cartridge Art.No. 5012

 

 

 

 9011 Pressure container

 Euro 3100 ml over piston

Pressure container with quick ventilation 

Size approx.:

765 x 255 x 133 mm (L / W / D)

9011 Behälterentleerung

 9012 Pressure container

 Euro 3100 ml 

Pressure container with quick ventilation

Size approx.:

765 x 255 x 133 mm (L / W / D)

9012 Behälterentleerung

 9116 Pressure container

 Euro 3100 ml

Pressure container with pneumatic cylinder

Size about.:

576x180x112 mm (L / W / D)

9116 Behälterentleerung Euro 310ml axiss Dosiertechnik

 9050 Pressure container

 600 ml Tube

Pressure container for material tube 600 ml

Size approx.:

435x 65 x 65 mm (L / W / D)

9050 Druckbehälter Schlauch 600ml Behälterentleernung axiss Dosiertechnik

 9040 Emptying system
 Grease 400 ml

Grease dispensing using  pheumatic piston stroke

Size about.:

435 mm (L) Ø 65 mm

9040 Behälterentleerung Fett - 400 ml.jpg